![background image](http://html1.mh-extra.com/html/omron/v700-series/v700-series_operation-manual_743606119.webp)
6-6
Section
Functions
111
6-6-7 Test
If the testing of communications between the Antenna and ID Tag is required,
use the test function so that the location of the Antenna and ID Tag and the rela-
tive speed of the ID Tag can be checked.
Before executing the TEST READ or TEST WRITE command, set the commu-
nications mode.
Set the communications mode with the Right,
Left, or 1 through 8 Keys.
Press the SET Key to enter the setting.
A-MT
Note Settings 7–QT, 8–QA, and 9–QR are not supported by this system. (They are
used for high-speed access tags.) Also, the setting A–MT represents the multi-
trigger mode (ME).
Test Read
Set the communications mode
to single trigger mode.
Set the start address and end
address.
Press the SET Key. Then the
number of retries and the data
of the ID Tag are displayed.
Test Write
Set the communications mode to
FIFO repeat mode.
Set the start address, end
address, and write data.
Press the SET Key. Then the
number of retries and the result
of the test are displayed.
Communications Mode
Setting