background image

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access Contact Lancer Customer Service for assistance as required.

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,  

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS

Lancer PN: 28-2843/04

Revision: October 2017

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should 

not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

75°F (4°C to 24°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

The refrigeration system is under high pressure. Do not tamper with it. Contact qualified service personnel before disposal.

Refrigerant Warning

®

9000

Summary of Contents for DELTA6 Series

Page 1: ...to the dispenser lies with the carrier The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practica...

Page 2: ...63 0 kg Operating 219 lbs 99 3 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand...

Page 3: ...e compressor to overheat and will result in compressor failure ATTENTION Selecting Preparing Counter Location The dispenser should only be installed in a location where it can be overseen by trained p...

Page 4: ...mp location to the syrup inlets located behind the splash plate Connect tubing to inlets using the oetiker pliers and fittings Repeat for all syrup connections If the unit being installed has built in...

Page 5: ...riate tubing from the syrup pump syrup supply location to the CO2 inlet and connect tubing to CO2 inlet If the water source is above 50 PSIG 0 345 MPA cut tubing assembly and install Water Regulator K...

Page 6: ...Carbonated Water Setup 1 Purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water comes out A Relief Valve Open B CO2 Inlet C CO2 Line A B C 2 Activate each...

Page 7: ...he water level Use a screwdriver to adjust if needed A B A Plain Water ON B Syrup Closed 9 Repeat process for each valve 10 Re install the merchandiser splash plate cup rest and drip tray then reattac...

Page 8: ...110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can ca...

Page 9: ...reates a health hazard CAUTION Cleaning and Sanitizing Nozzles 1 Disconnect power so as to not activate valve while cleaning 2 Remove nozzle by twisting counter clockwise and pulling down 3 Remove dif...

Page 10: ...10 WIRING DIAGRAM 115 V 60 Hz R744 WIRING DIAGRAM 230 V 50 Hz 220 V 60 Hz R744...

Page 11: ...M 115 V 60 Hz 230 V 50 Hz 220 V 60 Hz R134A PLUMBING DIAGRAM PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S1 PW1 S2 S3 S4 S5 S6 PLAIN WATER INLET TO CARBONATOR PLUMBING DIAGRAM CE...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...