background image

5

 

The water bath compartment must be filled with water 

before plugging in the unit, otherwise the compressor 

fan may not operate properly. DO NOT use RO or 

 

purified water.

ATTENTION

12.  Remove yellow cap from the water bath fill hole and insert 

and insert a funnel into the fill hole. 

13.  Carefully pour the distilled water mixture into the water bath 

tank until water flows out of the overflow tube at the front 

of the unit. Then replace yellow cap (Repeat steps 9-10 if 

needed)

 

Make sure the top of overflow tube is not covered so 

that the water from the water bath tank cannot escape.

NOTE

A

C

B

A. Tube from Water Bath

B. Overflow Tube

C. Top of Overflow Tube

A

B

C

A. Line to Water Source

B. Line To Plain Water Inlet

C. Line To Carb Water Inlet

D. “U” Fitting

D

14.  Using tubing cutters, cut water supply line and install “U” 

fitting, 

(PN 01-2128/01). 

15.  Route appropriate tubing from the the plain water inlet, 

located at the front of the unit, to one side of the “U” fitting at 

water supply and connect tubing to inlet.

16.  Route appropriate tubing from the carbonator pump inlet and 

the “U” fitting at water supply then connect tubing to inlet 

using flare seal washer 

(PN 05-0017). 

Use a back-up wrench 

to prevent damage to carbonator pump. 

A

B

C

A. Plain Water Inlet

B. Plain Water Line

C. Oetiker Pliers

D. Fitting

D

17.  Route appropriate tubing from the syrup pump/syrup supply  

location to the CO

2

 inlet and connect tubing to CO

2

 inlet. 

 

If the water source is above 50 PSIG (0.345 MPA), cut 

tubing assembly and install Water Regulator Kit 

(PN 

18-0253/02, sold separately)

 as shown in kit instruction 

sheet. Once installed, use a test gauge assembly 

(PN 

22-0138, sold separately)

, to set regulator at a 

 

maximum of 50 PSIG (0.345 MPA).

NOTE

A

B

C

A. Carbonator

B. Carb Water Inlet

C. Carb Water Line

D. Fitting

18.  Connect drain tube to the drain fitting located on the bottom 

of the drip tray and secure drain tube with clamp.  

19.  Feed all tubing, power cord, and drain line through the  

counter top cutout.

20.  Connect tubing routed from carbonated water inlet and plain 

water inlet to the “U” fitting at the water supply.

21.  Turn on water supply and check for leaks.  
22.  Route the drain line to designated floor drain.
23.  Plug in the unit to a grounded electrical outlet then turn the 

power switch, at the top of the unit, to begin building an ice 

bank.

A

B

C

A. CO

2

 Inlet

B. CO

2

 Line

C. Pressure Relief Valve

 

The dispenser must be properly electrically grounded 

 

to avoid serious injury or fatal electrical shock. The 

 

power cord has a three-prong grounded plug. If a 

 

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow all 

local electrical codes when making connections. Each 

 

dispenser must have a separate electrical circuit. Do 

 

not use extension cords. Do not connect multiple

 

electrical devices on the same outlet.

WARNING

Summary of Contents for DELTA6 Series

Page 1: ...to the dispenser lies with the carrier The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practica...

Page 2: ...63 0 kg Operating 219 lbs 99 3 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand...

Page 3: ...e compressor to overheat and will result in compressor failure ATTENTION Selecting Preparing Counter Location The dispenser should only be installed in a location where it can be overseen by trained p...

Page 4: ...mp location to the syrup inlets located behind the splash plate Connect tubing to inlets using the oetiker pliers and fittings Repeat for all syrup connections If the unit being installed has built in...

Page 5: ...riate tubing from the syrup pump syrup supply location to the CO2 inlet and connect tubing to CO2 inlet If the water source is above 50 PSIG 0 345 MPA cut tubing assembly and install Water Regulator K...

Page 6: ...Carbonated Water Setup 1 Purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water comes out A Relief Valve Open B CO2 Inlet C CO2 Line A B C 2 Activate each...

Page 7: ...he water level Use a screwdriver to adjust if needed A B A Plain Water ON B Syrup Closed 9 Repeat process for each valve 10 Re install the merchandiser splash plate cup rest and drip tray then reattac...

Page 8: ...110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can ca...

Page 9: ...reates a health hazard CAUTION Cleaning and Sanitizing Nozzles 1 Disconnect power so as to not activate valve while cleaning 2 Remove nozzle by twisting counter clockwise and pulling down 3 Remove dif...

Page 10: ...10 WIRING DIAGRAM 115 V 60 Hz R744 WIRING DIAGRAM 230 V 50 Hz 220 V 60 Hz R744...

Page 11: ...M 115 V 60 Hz 230 V 50 Hz 220 V 60 Hz R134A PLUMBING DIAGRAM PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S1 PW1 S2 S3 S4 S5 S6 PLAIN WATER INLET TO CARBONATOR PLUMBING DIAGRAM CE...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: