Before installing regulator, assure that a seal (washer 

or o-ring) is present in regulator attachment nut.

ATTENTION

Installing CO

2

 Supply

1.  Connect high pressure CO

2

 regulator assembly to CO

2

     

cylinder or bulk system.

Thread regulator nut on to tank, then   

 

tighten nut with wrench

A. CO

2

 Regulator

B. Outlet

C. Wrench

D. CO

Supply

A

B

C

D

2.  Connect a 1/4” nut, stem and seal to CO

2

 regulator outlet. 

Then connect tubing routed from tee at syrup pumps. 

3.  Using a wrench, loosen lock nut on regulator adjustment 

screw then using a screwdriver back out lock nut screw all 

the way. 

A. CO

2

 Regulator

B. 1/4” Nut, Stem & Seal

C. Line to Syrup Pumps

D. Oetiker Pliers

A

B

C

D

 

DO NOT TURN ON CO

2

 SUPPLY AT THIS TIME

WARNING

A. CO

2

 Regulator

B. Screwdriver

C. Loosened Lock Nut

D. Regulator Adjustment Screw

A

B

C

D

Carbonated Water Setup

1.  Purge water to fill carbonator tank by opening carbonator 

relief valve. Close relief valve once water comes out.

A. Relief Valve (Open)

B. CO

2

 Inlet

C. CO

2

 Line

A

B

C

2.  Activate each valve until a steady flow of water is achieved.
3.  Turn power off.
4.  Unplug the Pump Motor Connector from the control box. Use 

the wiring diagram either on the unit control box or in the 

back of this manual for reference. 

 

Pump Motor will run for a few seconds to fill carbonator 

tank

NOTE

 

Failure to disconnect the motor power supply will 

damage the carbonator motor, the pump and void the 

warranty.

ATTENTION

5.  Turn on CO

2

 and using a screwdriver, adjust regulator to 75 

PSI (0.517 MPA) then tighten lock nut with wrench. 

6.  Activate each valve until gas-out is achieved. 
7.  Plug the Pump Motor Connector back into the control box.
8.  Turn power on. 

A. Regulator Adjustment Screw

B. Adjust to 75 PSI (0.517 MPA)

C. Wrench

A

B

C

9.  Activate each valve until a steady flow of carbonated water is 

achieved. 

Summary of Contents for DELTA6 Series

Page 1: ...to the dispenser lies with the carrier The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practica...

Page 2: ...63 0 kg Operating 219 lbs 99 3 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand...

Page 3: ...e compressor to overheat and will result in compressor failure ATTENTION Selecting Preparing Counter Location The dispenser should only be installed in a location where it can be overseen by trained p...

Page 4: ...mp location to the syrup inlets located behind the splash plate Connect tubing to inlets using the oetiker pliers and fittings Repeat for all syrup connections If the unit being installed has built in...

Page 5: ...riate tubing from the syrup pump syrup supply location to the CO2 inlet and connect tubing to CO2 inlet If the water source is above 50 PSIG 0 345 MPA cut tubing assembly and install Water Regulator K...

Page 6: ...Carbonated Water Setup 1 Purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water comes out A Relief Valve Open B CO2 Inlet C CO2 Line A B C 2 Activate each...

Page 7: ...he water level Use a screwdriver to adjust if needed A B A Plain Water ON B Syrup Closed 9 Repeat process for each valve 10 Re install the merchandiser splash plate cup rest and drip tray then reattac...

Page 8: ...110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can ca...

Page 9: ...reates a health hazard CAUTION Cleaning and Sanitizing Nozzles 1 Disconnect power so as to not activate valve while cleaning 2 Remove nozzle by twisting counter clockwise and pulling down 3 Remove dif...

Page 10: ...10 WIRING DIAGRAM 115 V 60 Hz R744 WIRING DIAGRAM 230 V 50 Hz 220 V 60 Hz R744...

Page 11: ...M 115 V 60 Hz 230 V 50 Hz 220 V 60 Hz R134A PLUMBING DIAGRAM PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S1 PW1 S2 S3 S4 S5 S6 PLAIN WATER INLET TO CARBONATOR PLUMBING DIAGRAM CE...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: