6 Programming Features
163
Prohibiting Constant Read Selection (n177)
Select this function to prevent accidentally overwriting the constants
stored in EEPROM in the Digital Operator. Reading is not possible
when this constant is set to 0.
The constant data stored in the Digital Operator are safe from accidental
overwriting.
If reading is attempted while this constant is set to 0, PrE will flash.
Press
or
and return to the constant number display.
Constant
No.
Name
Unit
Setting Range
Factory
Setting
n176
Constant
Copy Func-
tion Selection
-
rdy: Ready
rEd: Read
CPy: Copy
vFy: Verify
vA: Inverter capacity display
Sno: Software No. display
rdy
Constant
No.
Name
Unit
Setting Range
Factory
Setting
n177
Constant Read
Selection Prohibit
-
0: Read prohibited
1: Read allowed
0
DSPL
ENTER