216
Control Circuit
Input
Se
qu
en
ce
S1
Multi-function input
selection 1
Factory setting closed: FWD run
open: Stop
Photocoupler
insulation, 24
VDC, 8 mA
S2
Multi-function input
selection 2
Factory setting closed: REV run
open: Stop
S3
Multi-function input
selection 3
Factory setting: External fault
(NO contact)
S4
Multi-function input
selection 4
Factory setting: Fault reset
S5
Multi-function input
selection 5
Factory setting: Multi-step speed
reference 1
S6
Multi-function input
selection 6
Factory setting: Multi-step speed
reference 2
S7
Multi-function input
selection 7
Factory Setting: Jog Command
SC
Multi-function input
selection common
For control signal
Fr
eq
ue
ncy re
fer
e
nc
e
RP
Master reference
pulse train input
33 kHz max.
FS
Power for frequency
setting
+12 V (permissible current 20 mA max.)
FR
Master frequency
reference
0 to +10 VDC (20 k
Ω
) or 4 to 20 mA (250 k
Ω
) or 0 to 20
mA (250
Ω
) (1/1000 resolution)
FC
Frequency reference
common
0 V
Output
M
ulti-f
un
ction
co
nt
a
ct o
ut
put
MA
NO contact output
Factory setting: fault
Contact capacity
250 VAC: 1 A or less,
*3
30 VDC: 1 A or less
MB
NC contact output
MC
Contact output
common
P1
Photocoupler output 1
Factory setting: Run
Photocoupler
48 VDC,
50 mA or less
P2
Photocoupler output 2
Factory setting: Frequency agree
PC
Photocoupler output
common
0 V
AM
Analog monitor output
*2
Factory setting:
Output frequency
0 to +10 V
0 to +10 VDC, 2 mA or less,
8-bit resolution
AC
Analog monitor
common
0 V
Type
Terminal
Name
Function (Signal Level)