80
Frequency Offset Selection (n146)
An offset frequency (which can be set with a constant) can be added to
or subtracted from the frequency reference using multi-function inputs.
Constant
No.
Name
Description
Factory
Setting
n083
Jump Frequency 1
(Offset Frequency 1)
1st digit of n146 is 0 or 1:
Setting unit: 0.01 Hz
Setting range: 0.00 to
400.0 Hz
1st digit of n146 is 2:
Setting unit: 0.01%
Setting range: 0.00% to
100.0% (Percentage of Maxi-
mum Output Frequency)
0.00 Hz
n084
Jump Frequency 2
(Offset Frequency 2)
1st digit of n146 is 0 or 1:
Setting unit: 0.01 Hz
Setting range: 0.00 to
400.0 Hz
1st digit of n146 is 2:
Setting unit: 0.01%
Setting range: 0.00% to
100.0% (Percentage of Maxi-
mum Output Frequency)
0.00 Hz
n085
Jump Frequency 3
(Offset Frequency 3)
1st digit of n146 is 0 or 1:
Setting unit: 0.01 Hz
Setting range: 0.00 to
400.0 Hz
1st digit of n146 is 2:
Setting unit: 0.01%
Setting range: 0.00% to
100.0% (Percentage of Maxi-
mum Output Frequency)
0.00 Hz