6 Programming Features
83
The following block diagram illustrates the Frequency Offset Function.
Operating a Coasting Motor without Tripping
To operate a coasting motor without tripping, use the Speed Search
Command or DC Injection Braking at Startup.
Speed Search Command
Restarts a coasting motor without stopping it. This function enables
smooth switching between motor commercial power supply operation
and Inverter operation.
Set a Multi-function Input Selection (n050 to n056) to 14 (Search Com-
mand from maximum output frequency) or 15 (Search Command from
set frequency).
Build a sequence so that a FWD (REV) Run Command is input at the
same time as the Search Command or after the Search Command. If the
Run Command is input before the Search Command, the Search Com-
mand will be disabled.
+
+
+
+
+
0
0
0
0
Selected
Frequency
Reference
n146,
right digit
Frequency
Reference
Upper Limit
n033 x n011
Jump Frequencies
Frequency
Reference
Lower Limit
400 Hz
n146,
right digit
n083
n084
n085
n034 x n011
Frequency
Reference
(U-01)
Frequency Offset
Input 1
Frequency Offset
Input 2
Frequency Offset
Input 3
n083
n084
n085
Offset
Volume
(U-12)