![background image](http://html.mh-extra.com/html/omron/sysmac-c200h-ov001/sysmac-c200h-ov001_operation-manual_1633422082.webp)
74
MOV
#1052
120
03003
MOV
#0205
121
MOV
#1600
122
00103
03006
12901
03003
03000
03003
DIFU
03000
00100
03006
03004
03001
03004
03007
03005
03002
03005
03008
DIFU
03001
00101
DIFU
03002
00102
12903
03006
03007
03008
03004 12901 12903
03005 12901 12903
To be continued
12015
12014
MOV
#0025
120
MOV
#1006
121
MOV
#3800
122
03007
MOV
#0106
120
MOV
#0948
121
MOV
#0000
122
03008
03006 03007
03006
In this program, when two inputs turn ON during the same scan time, the part
programmed first takes precedence. For example when inputs 00100, 00101,
and 00102 turn ON during the same scan time, the data for Message no. 1 is
transferred first followed respectively by Message nos. 2 and 3.
12901: Voice Unit busy flag
12903: Output message area FULL flag
Example 8:
In this example, two Voice Units are used to combine phrases.
Phrase Combination Mode Example Programs
Section 4-2