![background image](http://html.mh-extra.com/html/omron/sysmac-c200h-ov001/sysmac-c200h-ov001_operation-manual_1633422076.webp)
68
@MOV
#0102
120
12014
00100
@MOV
#0220
121
@MOV
#3500
122
DIFU
03000
@MOV
#102F
120
00101
@MOV
#0320
121
@MOV
#1342
122
DIFU
03001
03000
03001
@MOV
#0000
123
This command transfers repetition (2
times) and interval data (1.0 s) to the
Voice Unit (when input 00100 turns
ON).
This command sets Phrase no. 2 as
the first phrase and Phrase no. 20 as
the second phrase (when input
00100 turns ON).
This command sets Phrase no. 35 as
the third phrase and Phrase no. 00 as
the fourth and last (Phrase no. 00
signifies the last phrase) phrase (when
input 00100 turns ON).
This command transfers repetition
(continuously) and interval data (0.2 s)
and the priority command to the Voice
Unit (when input 00101 turns ON).
This command sets Phrase no. 3 as
the first phrase and Phrase no. 20 as
the second phrase (when input 00101
turns ON).
This command sets Phrase no. 13 as
the third phrase and Phrase no. 42 as
the fourth phrase (when input 00101
turns ON).
This command sets Phrase no. 00 as
the fifth and last (Phrase no. 00 signi-
fies the last phrase) phrase (when input
00101 turns ON). Note the specification
of sixth phrase, in this example 00, is
arbitrary if the preceding phrase is the
last one.
This command issues the message
output command.
The messages, for the above program, are issued as follows:
When input 00100 turns ON, the message “No. 2 Tank Needs Water” is
played back twice at 1.0 second intervals.
When input 00101 turns ON, the message “No. 3 Tank Has A Problem” is
played back continuously at 0.2 second intervals. This message takes prece-
dence over the other message.
To stop the continuous playback of a message turn ON the stop command.