64
The number of repetitions and repeat intervals are as follows:
Number of repetitions
Repeat intervals
Message no. 12
Message no. 7
3 times
0.2 s
Continuously
0.5 s
Message no. 25
5 times
1.0 s
00100
@MOV
#0023
110
03001
03000
DIFU
11112
00101
03001
11107
11503
DIFU
03000
MOV
#005F
110
03001
11112
11503
11107
03003
03002
00102
03003
11210
DIFU
03002
MOV
#0105
110
03003
11112
11107
11210
11100
00103
11503
In this program, if two or more
inputs turn ON during the same
scan time, the output command
programmed first takes prece-
dence. For example when in-
puts 00100, 00101, and 00102
turns ON during the same scan
time, then Message no. 12 is
transferred first followed respec-
tively by Message no. 7 and
Message no. 25.
11503 is the output message
area FULL flag
Example 7: Level operation
Message no. 16 is played back while input 00100 is ON.
Message no. 33 is played back while input 00101 is ON.
Sentence Mode Example Programs
Section 4-1