47
One-shot operation in sequential mode
1
2
3
19
20
No. 10
No. 1
No. 6
No. 2
No. 25
No. 3
Message area during playback
Output message area
(FULL status)
Messages are stored in
the sequence in which
their output commands
have turned ON. If more
than one output com-
mand turns ON at the
same time, the message
having the lower number
is stored.
The new output command is not
accepted even if it turns ON.
Message no. 3 has
been played back.
No. 10
Message area during playback
Output message area
1
2
3
19
20
No. 1
No. 6
No. 12
No. 25
The new output command
is accepted if it turns ON.
Vacant
One-shot operation in priority mode
1
2
3
19
20
No. 5
No. 6
No. 7
No. 32
No. 35
No. 3
Message area during
playback
Output message area
(FULL status)
No. 2
Message area during
playback
Output message area
(FULL status)
No. 3
No. 5
No. 6
No. 29
Messages whose output
command have turned ON
are stored, beginning with
the message having the
lowest message number.
Only the output command of
a message having a lower
message number than those
of the messages in the mes-
sage area is accepted.
The output command of
message no. 2 turns ON.
Message No. 35 is
canceled.
No. 32
1
2
3
19
20
The output message area FULL flag turns ON in response to the output com-
mand during OUT refreshing when the number of messages stored in the
storage area reaches 20, and when the input data in the same I/O refresh
area is refreshed. During the next input refreshing, when the number of mes-
sages decreases to 19 or less, the flag turns OFF.
ON-LINE Mode
Section 3-8