36
(2)
Select communication modes (displayed on the MSG no. indicator
display) with the MSG no. increment/decrement switch.
MSG No. increment switch
MSG No. decrement switch
MSG No. and communication mode
(x10 digit)
No.
Baud rate (bps)
XON/XOFF (yes/no)
0
2400
no
1
4800
2
9600
3
19200
4
2400
yes
5
4800
6
9600
7
19200
(x1 digit)
No.
Transfer range (bits)
RTS/CTS (yes/no)
0
All data (1M byte)
no
1
First half (512K bytes)
2
Second half (512K bytes)
3
All data (1M byte)
yes
4
First half (512K bytes)
5
Second half (512K bytes)
Example
(x10)
(x1)
When communication mode shown on the
Message no. indicator display is set to “63”
Baud rate
: 9,600 bps
XON/XOFF control
: valid
Range
: all data (1M bit) of message
memory
RTS/CTS control
: valid
LED display
For the set number, refer to the table on the previous page.
Transfer Method
Confirm that the transmit standby status is set, that the necessary communi-
cation mode is set, and that the external device is ready for reception. Then
push the ST/SP switch.
During data transfer the PLAY indicator blinks at high speed (in synchroniza-
tion with data transmission.)
XMT/RCV Mode
Section 3-7