85
Errors in RCV mode
Display
Possible Cause
Correction
RUN
PLAY
REC
ERR
OVF
The memory protect switch is ON (in
this situation the error indication is
made when the mode selector switch is
operated or when the ST/SP switch is
pressed).
Turn OFF the memory protect switch
and start reception.
The RUN and ERR indicators are
lit. The REC indicator is blinking at
0.2
second intervals.
The LEDs display a communication
mode.
The ST/SP switch was pressed while
data was being received.
Begin the data reception procedure
from the beginning.
An error occurs in the data received.
Remove the cause of the error and
begin the data reception procedure
from the beginning
Note
: lit,
: blinking at 0.5 s intervals,
: blinking at 0.2 s intervals
: blinking at high speed
ÇÇ
ÇÇ
5-2
Troubleshooting
Recording
Error
Possible Cause
Correction
Message cannot be recorded
The message input jack is not
connected correctly.
Check the connection of the plug
connected to the message input jack.
The microphone switch is OFF.
Turn ON the switch.
The volume control of the tape
recorder is at the MIN. position.
Adjust the volume control.
The input volume control of the Voice
Unit is at the MIN. position.
Turn the input volume control
clockwise toward the MAX. position
and adjust the volume.
Pin 4 of the DIP switch on the back
panel of the Voice Unit is ON.
Turn OFF the power to the PC,
remove the Unit, and turn OFF pin 4 of
the DIP switch.
The line/microphone selector switch is
set to the wrong position.
Check the setting of the
line/microphone selector switch.
The Voice Unit is defective.
Replace the Unit.
Message cannot be recorded
(The ERR indicator is lit )
Refer to the error code.
Refer to the error code.
Message cannot be recorded
(All indicators are unlit )
Refer to the error code.
Refer to the error code.
The sound of the message is distorted.
The message input level is too high.
Adjust the input volume control. When
using a tape recorder, also adjust the
volume control of the tape recorder.
The volume of the message is low
even when the input volume control is
turned to the maximum position.
The impedance of the microphone
does not match that of the Voice Unit.
Check the impedance of the
microphone.
The impedance or output level of the
tape recorder do not match those of
the Voice Unit.
Check the impedance and maximum
level of the tape recorder.
Troubleshooting