63
MOV
#0203
110
11109
03001
03000
DIFU
03000
00100
03001
TIM000
TIM000
03001
In this section while TIM00 is OFF
(time not up) the ON status of input
00100 is maintained. During this time
the transfer of data and message no.
9’s output command to the Voice Unit
occurs. The transfer is terminated
when TIM000 turns ON (time up).
Timer value > Transfer time + Scan
time (max.)
In this example, the output storage area becomes full.
Message no. 21 is played back two times at 1.0 second intervals when input
00100 turns ON.
MOV
#0102
110
03001
03000
DIFU
03000
00100
03001
11206
11206
03001
11503
This section maintains the ON sta-
tus of input 00100 until it is can-
celed by the turning ON of message
no. 21’s output command (11206)
This section only transfers the
number of repetitions and repeat
intervals to the Voice Unit when
the output message area FULL
flag (11503) is ON; at the same
time Message no. 21’s output
command is issued.
In this example an Input Unit is assigned to word 1 and unit no. 1 is assigned
to the Voice Unit.
Message no. 12 is played back when input 00100 turns ON.
Message no. 7 is played back when input 00101 turns ON.
Message no. 25 is played back when input 00102 turns ON.
Message playback is stopped when input 00103 is ON.
Example 5: One-shot
operation in sequential
mode
Example 6: One-shot
operation in sequential
mode
Sentence Mode Example Programs
Section 4-1