75
Diagnostic Flowcharts
Section 4-3
4-3
Diagnostic Flowcharts
If an error occurs, determine the conditions under which it occurs: intermittent
or continuing; on-line or off-line.
Use the following flowcharts to determine the cause of an error.
Basic Assurance Test (BAT)
START
Turn the power
to the PC ON
OK
RUN LED
unlit
lit
T/R LED
lit
unlit
Hardware error
Replace the ID
Sensor Unit
blinking
PC ERROR
LED
Locate the error
in the PC and
correct it.
lit