59
Monitoring
Section 3-2
3-2-4
Address/Data Setting
Before executing the Read (READ), Step Write (WRITE 1), Continuous Write
(WRITE 2), or Test (TEST) commands, you must specify the Data Carrier
address to be accessed and the data (1 byte) to be written to that address.
This section explains the procedure for specifying the data, selecting the
addresses, and setting the addresses and data. The data and addresses that
must be set before the execution of each command are shown in the following
table.
Once the data is set in the specified address range, it will be retained until the
data is set again. Therefore, the same address can be accessed as many
times as required by pressing the command key.
Note
1.
Items marked
•
must be set.
2.
Set an end address whose value is equal to or greater than that of the
specified start address.
Selecting Start and End
Addresses
First, select a start or end address. Refer to the diagram below in selecting
either the start address or the end address of a specific page. Once selected,
the desired values can be input.
Note
This operation displays only the current addresses; it cannot be used to
change an address
.
Command
Address
Data
Start address
End address
READ
•
−
−
WRITE 1 (Step Write)
•
−
•
WRITE 2 (Continuous Write)
•
•
•
TEST 1 (Read)
•
•
−
TEST 2 (Write)
•
•
•
TEST 3 (Auto Read)
•
•
−
TEST 4 (Auto Write)
•
•
•
HEAD 1 PAGE 1
STadrs00 data 00
HEAD 1 PAGE 1
EDadrsFF data 00
Start
address
or
End
address
"FF" is displayed on
power application.
Press the RESET button to display the
reset screen, as shown on the left.
Pressing the left or right arrow key al-
ternately displays the current start and
end addresses.
RESET
Summary of Contents for SYSMAC C200H-IDS01-V1
Page 1: ...OPERATION MANUAL ID Sensor SYSMAC C200H IDS01 V1 IDS21 Cat No W153 E1 04...
Page 3: ...iv...
Page 5: ...vi...
Page 7: ...viii TABLE OF CONTENTS Glossary 89 Index 91 Revision History 95...
Page 9: ......
Page 15: ...xvi Application Precautions 5...
Page 25: ......
Page 95: ......
Page 97: ......
Page 99: ......
Page 103: ......
Page 109: ......
Page 111: ......
Page 114: ...SYSMAC C200H IDS01 V1 IDS21 ID Sensor Cat No W153 E1 04 OPERATION MANUAL...