64
Monitoring
Section 3-2
3-2-7
Continuous Write (WRITE 2)
This operation continuously writes several bytes of the same data to a speci-
fied address range in the Data Carrier. Refer to the following figure.
Before performing this operation, select the address and the data you want to
write. Refer to
3-2-4 Address/Data Setting
for details
.
HEAD 1 PAGE 1
STadrs1F data 54
HEAD 1 PAGE 1
CWadrs1F data 54
HEAD 1 PAGE 1
CWadrs28 data 54
HEAD 1 PAGE 1
CWadrs3F data 54
HEAD 1 PAGE 1
CWadrs32 NO DC E
HEAD 1 PAGE 1
CWadrs1F data 72
Indicates that Continuous
Write will be executed.
Data to be written
Error
message
Error code number
Normal
completion
When an
error occurs
Data to
be written
HEAD 1 PAGE 1
STadrs1F data 54
ST: start address
ED: end address
start address
≥
end address
start
address
End address
Address at which an
error has occurred
Select the start and end ad-
dresses, as well as the data
to be written.
Press the WRITE 2 key.
"CW" is displayed in the low-
er left corner of the Pro-
gramming Console display,
indicating that Continuous
Write is being executed. The
data is written to the
addresses in the range spe-
When the data is written cor-
rectly to all addresses and the
Continuous Write operation is
completed, the written data
appears as shown in the
example.
Pressing the left or right
arrow key will toggle the dis-
play between the error mes-
sage and the corresponding
error code.
If an error occurs during the
Continuous Write operation,
the buzzer sounds for 2
seconds, and an error mes-
sage is displayed (refer to
).
To perform another opera-
tion or abort the Continuous
Write operation, press the
RESET key, and the display
will return to reset status. In
this example, the display
indicates the reset status.
Another operation can now
be performed.
or
start
address/
data setting
WRITE
2
RESET
cified.
3-2-10 Error Codes
Summary of Contents for SYSMAC C200H-IDS01-V1
Page 1: ...OPERATION MANUAL ID Sensor SYSMAC C200H IDS01 V1 IDS21 Cat No W153 E1 04...
Page 3: ...iv...
Page 5: ...vi...
Page 7: ...viii TABLE OF CONTENTS Glossary 89 Index 91 Revision History 95...
Page 9: ......
Page 15: ...xvi Application Precautions 5...
Page 25: ......
Page 95: ......
Page 97: ......
Page 99: ......
Page 103: ......
Page 109: ......
Page 111: ......
Page 114: ...SYSMAC C200H IDS01 V1 IDS21 ID Sensor Cat No W153 E1 04 OPERATION MANUAL...