52
Monitoring
Section 3-2
3-2-2
Mode Setting
The Handheld Programming Console can be operated in three modes; the
functions and applications of these modes are outlined in the following table.
Use the Mode selector switch on the Handheld Programming Console to
select the mode.
Note that these modes apply only to the ID Sensor Unit; they do not apply to
the CPU.
Programming Console Key Layout
Programming Console Modes
Mode
Function
Application
RUN
In this mode, the CPU transfers data to and from the Data
Carrier according to the program in the CPU. It is a normal
operating mode only; no key input is possible.
Set the ID Sensor to RUN mode for normal
operation.
MONITOR
In this mode, use Read,
Write, Continuous Write,
and Step Write to monitor
data communication
between the ID Sensor
and the Data Carrier. In
this mode, the ID Sensor
Unit operates only via
commands input from the
Handheld Programming
Comsole; commands
from the CPU are
ignored.
The ID Sensor Unit reads/
writes data directly from/to the
Data Carrier.
An easy operation test such as Read, Step
Write or Continuous Write can be performed
when installing the ID Sensor.
The ID Sensor Unit repeatedly
executes Read, Write, Auto
Read, or Auto Write. If an
error occurs, the correspond-
ing error code is displayed on
the Programming Console.
(Refer to
3-2-10 Error Codes
.)
Use this mode to test (TEST) and adjust the
speed of the Data Carrier and the distance
from the Read/Write Head (or Antenna).
Any communication error that
has occurred in RUN mode is
displayed on the Program-
ming Console.
If an error occurs, use MONITOR mode to
determine the cause. (Refer to
3-2-9 Error
Log Display (ERR)
.)
PROGRAM
Not used.
–––
Mode selector switch
C500-IDS01-V1
Summary of Contents for SYSMAC C200H-IDS01-V1
Page 1: ...OPERATION MANUAL ID Sensor SYSMAC C200H IDS01 V1 IDS21 Cat No W153 E1 04...
Page 3: ...iv...
Page 5: ...vi...
Page 7: ...viii TABLE OF CONTENTS Glossary 89 Index 91 Revision History 95...
Page 9: ......
Page 15: ...xvi Application Precautions 5...
Page 25: ......
Page 95: ......
Page 97: ......
Page 99: ......
Page 103: ......
Page 109: ......
Page 111: ......
Page 114: ...SYSMAC C200H IDS01 V1 IDS21 ID Sensor Cat No W153 E1 04 OPERATION MANUAL...