Setting Measurement Items
80
ZFX-C User’s Manual
Count
This item uses the changes in brightness in a region to detect edge(s). This item finds the edges of a specified
color (dark/light) in a single measurement region, and outputs the number, width and pitch of the edges.
Region settings
This function sets the measurement region.
X
MENU mode - [Setup] - [Item] - [Region]
Threshold
This function sets the judgment conditions.
X
MENU mode - [Setup] - [Item] - [Limits]
Item
Description
Measurement region
This function sets the region to be measured.
Setting the Region p.213
Reference registration
When the measurement region is set, measurement is executed on the display image,
and the result of execution is registered as the reference value. To re-register only refer-
ence values, you can use this function to re-register only reference values based on the
image currently on screen.
Setup Item
Description
Number of edges
Sets the range of the number of edges to be judged as OK.
Range: 0 to 255
Average pitch
Sets the range of the edge pitch to be judged as OK.
Range: 0 to 9999.999
(When calibration is OFF, the range becomes 0 to 640.)
Average width
Sets the range of the edge width to be judged as OK.
Range: 0 to 9999.999
(When calibration is OFF, the range becomes 0 to 640.)
Setup
Measurement
Measurement region
Target color: dark
Width
Number of edges
Pitch (distance between mid points)
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...