![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245166.webp)
Signal I/O
ZFX-C User’s Manual
6
PARALLE
L INTERFACE
163
In the above table, a “0” indicates the signal is OFF, a “1” indicates the signal is ON. A “*” indicates that the
ZFX-C does not read the bit status, so the bit status can be either 0 or 1.
Example
Clear error
Clears the error output results.
The parallel output signal (ERROR) is
turned OFF to turn the ERROR LED OFF.
1
0
1
0
0
0
0
1
Clear parallel
terminal
Clears the parallel output signals (OR,
DO0 to DO15).
1
0
1
0
0
0
1
0
Command
Description
Command code Parameter (binary code)
DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
Bank switching
Switching to bank 0.
0
1
0
0
0
0
0
0
Switching to bank 1.
0
1
0
0
0
0
0
1
Switching to bank 2.
0
1
0
0
0
0
1
0
:
:
Switching to bank 31.
0
1
0
1
1
1
1
1
Bank group switching
Switching to bank group 0.
1
1
0
0
0
0
0
0
Switching to bank group 1.
1
1
0
0
0
0
0
1
Switching to bank group 2.
1
1
0
0
0
0
1
0
:
:
Switching to bank group 31.
1
1
0
1
1
1
1
1
Model re-registration
Re-registering the model of item 0.
1
0
0
0
0
0
0
0
Re-registering the model of item 1.
1
0
0
0
0
0
0
1
Re-registering the model of item 2.
1
0
0
0
0
0
1
0
:
:
Re-registering the model of item 31.
1
0
0
1
1
1
1
1
Command
Description
Command code Parameter (binary code)
DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...