![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245054.webp)
Setting Measurement Items
ZFX-C User’s Manual
3
SETTING THE MEAS
UREM
ENT CONDITIONS
51
Graphic Search
Use this item when it is difficult to search for a model from partially clipped images or low-contrast images. The
degree of match indicating how much parts resemble each other and the position of the measurement object
can be output.
Comparison with Pattern Search
Region settings
This function sets the region to be registered as the model and the region to search for the model.
X
MENU mode - [Setup] - [Item] - [Region]
This item is not provided for the ZFX-C10/C15.
In a pattern search, a model of the image pattern is used with priority given to contrast information. However, in a
graphic search, a model with priority given to profile information is used.
Item
Description
Register model
This function registers the image pattern to find as the model.
Reference model
The image that is registered as the model can be referenced.
Search region
Set the region in which to search for the model.
Reference point
Set the coordinates of which part of the model are to be output. The default is the center
position of the model.
Note
Setup
Measurement
Parts resembling the model are searched for stably even
in the following environments.
Search region
(region for searching
model)
Reference point
Model
Register the profile information of the image
pattern to find.
Lots of noise
Partially clipped
Low contrast
Inclined
Note
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...