![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245089.webp)
Setting Measurement Items
86
ZFX-C User’s Manual
Possible output results
The following values can be output when expressions are set.
For details on reference position, position difference p.50
Item
Description
Message
Judgment result
The judgment result is output. (0: OK, -1: NG, -2: not measured)
Judge (JG)
Edge angle
The measured angle is output. (-180 to 180)
Angle (TH)
Edge position
The X, Y coordinates of the edge position are output. (-9999.999 to
9999.999)
Position X, Y
(X, Y)
Reference angle
The angle when the measurement region is set is output. (-180 to 180) Ref. angle (ST)
Reference position
The X, Y coordinates of the edge position when the measurement
region is set are output. (-9999.999 to 9999.999)
Reference X, Y
(SX, SY)
Angle difference
The difference obtained by "measurement angle - reference angle " is
output. (-360 to 360)
Angle dif. (DT)
Position difference
The difference obtained by "measurement position - reference position"
is output. (-9999.999 to 9999.999)
Position dif. X, Y
(DX, DY)
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...