Internal Specifications
160
ZFX-C User’s Manual
Internal Specifications
Input Specifications
RESET, DI0 to DI8, and DSA signals
TRIG signal
*1: The ON current/voltage is the value of the current/voltage that changes the status from OFF to ON. The
value of the ON voltage is the potential difference between COM IN and each input terminal.
*2: The OFF current/voltage is the value of the current/voltage that changes the status from ON to OFF. The
value of the OFF voltage is the potential difference between COM IN and each input terminal.
*3: The ON/OFF delay time for TRIG signal is different from the circuit diagram for RESET, DI0 to DI8, and DSA signals.
Mode
NPN
PNP
Input voltage
12 to 24 VDC ±10%
12 to 24 VDC ±10%
ON current *1
5 mA min.
5 mA min.
ON voltage *1
8.8 V min.
8.8 V min.
OFF current *2
0.5 mA max.
0.5 mA max.
OFF voltage *2
1.1 V max.
1.1 V max.
ON delay
5 ms max.
5 ms max.
OFF delay
0.7 ms max.
0.7 ms max.
Internal circuit
diagram
Mode
NPN
PNP
Input voltage
12 to 24 VDC ±10%
12 to 24 VDC ±10%
ON current *1
5 mA min.
5 mA min.
ON voltage *1
8.8 V min.
8.8 V min.
OFF current *2
0.5 mA max.
0.5 mA max.
OFF voltage *2
0.8 V max.
0.8 V max.
ON delay
0.1 ms max.
0.1 ms max.
OFF delay
0.1 ms max.
0.1 ms max.
Internal circuit
diagram
COMIN
Respective
terminal
COMIN
Respective
terminal
COMIN
Respective
terminal
COMIN
Respective
terminal
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...