Setting Measurement Items
82
ZFX-C User’s Manual
Possible output results
The following values can be output when expressions are set.
Edge level
With the count function, the edge is detected by deriva-
tive distribution.
1.The amount of change in directions light
→
dark and
dark
→
light is calculated.
2.The place where the amount of change exceeds the
edge level is detected as the edge.
Item
Description
Message
Judgment result
The judgment result is output. (0:OK, -1:NG, -2: not measured)
Judge (JG)
Number of edges
The number of detected edges is output. (0 to 255)
Number of edges (N)
Average pitch
The average detected pitch is output. (0 to 9999.999)
Average pitch (P)
Minimum pitch
The minimum detected pitch is output. (0 to 9999.999)
Min. pitch (PL)
Maximum pitch
The maximum detected pitch is output. (0 to 9999.999)
Max. pitch (PH)
Average width
The average detected edge width is output. (0 to 9999.999)
Average width (W)
Minimum width
The minimum detected edge width is output. (0 to 9999.999)
Min. width (WL)
Maximum width
The maximum detected edge width is output. (0 to 9999.999)
Max. width (WH)
Note
Measurement region
Max. density difference
value
Edge level
Min. density difference
value
100%
50%
0%
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...