![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245164.webp)
Internal Specifications
ZFX-C User’s Manual
6
PARALLE
L INTERFACE
161
Output Specifications
OR, ERROR, RUN, ENABLE, GATE, DO0 to DO15 signals
STGOUT 0 to 1 signals
Connect a load that matches the output specifications. Otherwise, a short-circuit may occur, which will cause
the Controller to break down.
Mode
NPN
PNP
Output voltage
12 to 24 VDC ±10%
12 to 24 VDC ±10%
Load current
45 mA max.
45 mA max.
ON residual voltage
2 V max.
2 V max.
OFF leakage current
0.2 mA max.
0.2 mA max.
Internal circuit
diagram
Mode
NPN
PNP
Output voltage
12 to 24 VDC ±10%
12 to 24 VDC ±10%
Load current
45 mA max.
45 mA max.
ON residual voltage
2 V max.
2 V max.
OFF leakage current
0.2 mA max.
0.2 mA max.
Internal circuit
diagram
Respective
terminal Load
COMOUT
Respective
terminal
COMOUT
Load
COMIN
Load
Respective
terminal
COMOUT
COMOUT
Load
Respective
terminal
COMIN
Important