![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245078.webp)
Setting Measurement Items
ZFX-C User’s Manual
3
SETTING THE MEAS
UREM
ENT CONDITIONS
75
Possible output results
The following values can be output when expressions are set.
For details on reference position, position difference p.50
Coordinates mode
Sets correction of the output coordinate system at output of the position information to ON/OFF.
Item
Description
Message
Judgment result
The judgment result is output. (0:OK, -1:NG, -2: not measured)
Judge (JG)
Edge position
The X, Y coordinates of the edge position are output.
(-9999.999 to 9999.999)
Position X, Y
(X, Y)
Reference position
The X, Y coordinates of the edge position when the measurement
region is set are output. (-9999.999 to 9999.999)
Reference X, Y
(SX, SY)
Position difference
The difference obtained by "measurement position - reference
position" is output. (-9999.999 to 9999.999)
Position dif. X, Y
(DX, DY)
Note
R
egistered image
Input image
C
oordinate system correction
O
FF
C
oordinate system correction
O
N
0
0
The position information of the
input image coordinate system
itself is output.
W
hen position shift correction is
set
,
the position of the
measurement region is corrected
by the amount of calculated shift.
W
hen position shift correction is set
,
the position information is output using
the coordinate system corrected to the
original state when the coordinate
system was registered.
In this example
,
edge position
O
K/N
G
can be judged using only the Y-axis
coordinate threshold value.
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...