Setting Measurement Items
68
ZFX-C User’s Manual
Threshold
This function sets the judgment conditions.
Judgment is performed on corresponding label Nos.
X
MENU mode - [Setup] - [Item] - [Limits]
Detailed settings (if necessary)
When measurement is not stable, adjust the detailed conditions.
X
MENU mode - [Setup] - [Item] - [Detail]
Setup Item
Description
Area
Sets the range of the area to be judged as OK.
Range: 0 to 9999999.999 (When calibration is OFF, the range of the area becomes 0 to
307200.)
Gravity XY
Sets the range of movement in the X- and Y-axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999 (When calibration is OFF, the range of movement for posi-
tions X and Y are 0 to 640 and 0 to 480, respectively.)
Number of labels
Sets the number of labels of the measurement target to be judged as OK.
Range: 0 to 65535
Axis angle
Sets the rotating range of the measurement target to be judged as OK.
Range: -90.0 to 90.0
+/- direction of angle
p.64
Perimeter
Sets the perimeter of the measurement target to be judged as OK.
Range: 0 to 9999999.999 (When calibration is OFF, the range of the perimeter becomes 0
to 200000.)
Length XY
Sets the X and Y lengths of the box circumscribing the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999 (When calibration is OFF, the range of movement for posi-
tions X and Y are 0 to 640 and 0 to 480, respectively.)
Roundness
Sets the roundness of the measurement target to be judged as OK.
Range: 0 to 1.0
Setup Item
Setting value
Description
Labeling mode
Precision
The image is measured without being compressed.
Normal (default value)
The image is measured at high speed after being compressed
to 1/2 size in both the horizontal and vertical directions.
Sort mode
Area descending order
(default value)
Re-assigns label Nos. in order of the largest area.
Area ascending order
Re-assigns label Nos. in order of the smallest area.
X gravity descending order Re-assigns label Nos. in order of the largest X gravity coordinate.
X gravity ascending order
Re-assigns label Nos. in order of the smallest X gravity coordinate.
Y gravity descending order Re-assigns label Nos. in order of the largest Y gravity coordinate.
Y gravity descending order Re-assigns label Nos. in order of the smallest Y gravity coordinate.
Label No.
0 to 2499 (default value: 0) Sets the label No. whose data is to be output.
Measure axis angle
OFF (default value)
When set to "ON", the axis angle is calculated.
ON
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...