![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245032.webp)
Mounting and Connecting Devices
ZFX-C User’s Manual
1
BEFORE USE
29
Connecting the Camera to the Controller
1
Insert the camera’s connector into the Controller’s
Camera connector.
2
Tighten the two fastening screws of the Controller’s
Camera connector.
Tightening torque: 0.15 N•m.
In a camera only connection, the tightening torque on the
camera side is 0.15 N•m.
•Do not touch the terminals inside the connector.
•Fasten the connector while making sure that it is not subjected
to vibration or shock.
•Do not mount the Controller in such a way that a load is steadily
applied on the connector, for example, with tension applied to
the cables.
To extend the installation distance between cameras and the Controller, see p.15
Disconnection procedure
Loosen the fastening screws (two locations) to unlock the camera’s cable, and then pull the camera’s cable
connector straight out.
• Be sure to hold the connector of the camera to disconnect it. Failure to do so may damage the camera’s cable.
• Do not touch the terminals inside the connector.
Important
Important