Setting Measurement Items
54
ZFX-C User’s Manual
Detailed settings (if necessary)
When measurement is not stable, adjust the detailed conditions.
X
MENU mode - [Setup] - [Item] - [Detail]
• Verification and Candidate level p.49
• Search Rotation Range p.49
• Setting the Candidate level p.49
• Coordinates mode p.75
Setup Item
Setting value
Description
Search mode
Hi-speed
The search is performed at high speed.
Normal (default value)
The search is performed in the normal mode.
Precision
The position is calculated at high precision in sub-pixel units
(units smaller than pixels).
Rotation range
0 to 180°
(default value: 0)
Sets in which angle range the model (rotated in degree units) is
to be created. The smaller the skipping angle that is set, the
higher the precision becomes, however, the longer the pro-
cessing time becomes.
When the rotation range and skipping angle have been
changed, register the model again.
Skipping angle
1, 2, 3, 5, 10, 15, 20, 30°
(default value: 10°)
Interpolation
OFF (default value)
Calculates the angle in skipping angle units.
ON
The angle is calculated as a numerical value down to three digits
past the decimal point based on the value obtained in skipping
angle units. Note, however, that the processing time increases.
This function is enabled only when the search mode is the nor-
mal mode or the precision mode.
Candidate level
0 to 100
(default value: 60)
Sets the level at which the model is searched for during a rough
search.
Images having a value of the degree of match at the candidate
level or more are taken to the candidate points in the Verifica-
tion. Set a lower level when the model cannot be searched for
stably.
Noise level
0 to 255
(default value: 8)
Sets the level at which profile information is searched during
measurement.
Profile information is obtained from the change in light intensity.
Locations having a light intensity at the noise level or higher are
picked up as the profile. Locations having a lower light intensity
are judged as noise components.
Adjusting this level has the following effect.
Calibration
OFF (default value)
Measurement results are output using the camera's coordinate values.
ON
Measurement results are output using the coordinate value
converted by the calibration function.
Coordinates mode
Normal (default value)
The position information of the input image coordinate system
itself is output.
Pos. correction
When position shift correction is set, the position information is
output using the coordinate system corrected to the original
state when the coordinate system was registered.
Important
L
o
w
High
N
o
i
se
l
eve
l
F
a
s
t
L
o
w
Sl
o
w
High
P
rocess
i
ng
t
i
me
C
ontrast
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...