System Settings
ZFX-C User’s Manual
5
ADDITIONAL
FUNCTIONS
137
Normal
Set the conditions required for performing serial communications in the normal mode.
X
MENU mode - [System] - [Comm] - [Normal]
Parallel Communication
Parallel communication
Set the conditions required for performing parallel communications.
X
MENU mode - [System] - [Comm] - [Parallel]
Parity
None (default value), Even, Odd
Stop bits
1 bit (default value), 2 bits
Setup Item
Setting value
Delimiter
CR (default value), LF, CR+LF
Setup Item
Description
Polarity
Sets the ON condition when the judgment result is output to the DO0 to DO15 and OR sig-
nals.
NG: ON: Signals turn ON when the judgment is NG. (default value)
OK: ON: Signals turn ON when the judgment is OK.
Output cycle
Sets the output cycle for the measurement results. Set a time that is "Gate ON delay +
Gate ON time" or more and that is shorter than the measurement cycle.
Range: 2.0 to 10000.0 ms (default value: 10.0 ms)
Gate ON delay
Sets the time from output of the measurement result to the DO0 to 15 signals until the
GATE signal turns ON. This is the time to wait until stable output data can be obtained. Set
a value longer than the ON delay/OFF delay time of the external device.
Range: 1.0 to 1000.0 ms (default value: 0.0 ms)
Gate ON time
Sets the time that the GATE signal is ON. Set a value that allows the external device to
capture the measurement result.
Range: 1.0 to 1000.0 ms (default value: 5.0 ms)
Handshaking
Sets the output method for the measurement results.
OFF: Measurement results are output asynchronously with external devices.
(default value)
ON: Measurement results are output synchronously with external devices.
Timeout
Sets the time until the timeout error is output. A timeout error occurs when there is no
response from the external device within the preset time.
Range: 1.0 to 60.0 s (default value: 10.0 s)
Setup Item
Setting value
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...