![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245186.webp)
Specifications and External Dimensions
ZFX-C User’s Manual
7
APPENDICES
183
ZFX-SC10/SC50/SC50W/SC90/SC90W/SC150/SC150R/SC150W (color type)
*1:
Applicable standards IEC60825-1:1993 +A1:1997 +A2:2001, EN60825-1:1994 +A2:2001 +A1:2002
Item
ZFX-SC10
ZFX-SC50/SC50W
ZFX-SC90/SC90W
ZFX-SC150/SC150R/
SC150W
Detection range (H x V)
4.9 mm x 4.9 mm to
8.9 mm x 8.9 mm
(variable range)
9.8 mm x 9.8 mm to
49 mm x 49 mm
(variable range)
49 mm x 49 mm to
89 mm x 89 mm
(variable range)
89 mm x 89 mm to
148 mm x 148 mm
(variable range)
Setting distance (L)
34 mm to 49 mm
31 mm to 187 mm
67 mm to 142 mm
115 mm to 227 mm
Relationship between
setting distance and
detection range
Image capture element
All-pixel capture inter-line transfer type 1/3" CCD (color)
Effective number of pixels
659(H) x 494 (V)
Pixel size
7.4 µm (H) x 7.4 µm (V)
Shutter speed
1/170 to 1/20000 s
Partial function (partial capture)
1/2 partial, 1/4 partial
Image rate function
Not available
Frame rate
(at capture of entire screen)
90 fps
Lighting
Lighting method
Pulse lighting
LED
White LED
Type
Direct lighting
Guide light
Not available
Optional lighting I/F Not available
Available (ZFV-LT)
Not available
Indicator Class
*1
Class 1
Class 2
Class 2
Class 1
Ratings
Power supply
voltage (supplied
from Controller)
15 VDC
15 VDC, 48 VDC
Current
consumption
Approx. 200 mA
Approx. 350 mA (15 VDC: approx. 150 mA, 48 VDC: approx. 200 mA)
(including current consumption when optional lighting is connected)
Operation
environment
robustness
Ambient
temperature range
Operating: 0 to + 40°C, Storage: -20 to +65°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere No corrosive gases allowed
Degree of protection ZFX-SC___: IP65 (IEC60529), ZFX-SC___W: IP67 (IEC60529)
Dielectric strength 1000 VAC 50 Hz/60 Hz 1 min
Vibration resistance
(durability)
10 to 150 Hz Single-amplitude 0.35 mm Acceleration: 50 m/s
2
10 times for 8 min each in X, Y, and
Z directions
Shock resistance
(destructive)
150 m/s
2
3 times each in 6 directions (up/down, left/right, forward/backward)
Connection method
Cable built-in type (ZFX-SC___R: Robot cable length 2 m, Otherwise: Standard cable length 2 m)
Material
Case: ABS, mounting fixture: PBT
Weight
Approx. 200 g (including
mounting fixture and cable)
Approx. 270 g (including
mounting fixture and cable)
Approx. 300 g (including
mounting fixture and cable)
Approx. 600 g (including
mounting fixture and cable)
Accessories
mounting fixture
(ZFV-XMF) 1 p'ce,
Ferrite core 2 p'ces,
Instruction Sheet
mounting fixture
(ZFV-XMF2) 1 p'ce,
Ferrite core 2 p'ces,
Warning label 1,
Instruction Sheet
mounting fixture
(ZFV-XMF2) 1 p'ce,
Ferrite core 2 p'ces,
Warning label 1,
Instruction Sheet
Ferrite core 2 p'ces,
Instruction Sheet
Detection
range
V
H
49
mm
34
mm
4.9 mm
8.9 mm
Detection range (H)
(L)
Setting distance
9.8 mm
187
mm
31
mm
49 mm
Detection range (H)
(L)
Setting distance
142
mm
67
mm
49 mm
89 mm
Detection range (H)
(L)
Setting distance
89 mm
227
mm
115
mm
148 mm
Detection range (H)
(L)
Setting distance
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...