![background image](http://html1.mh-extra.com/html/omron/smart-sensor-zfx-c/smart-sensor-zfx-c_user-manual_1633245124.webp)
Additional Functions
ZFX-C User’s Manual
3
SETTING THE MEAS
UREM
ENT CONDITIONS
121
Erasing Measurement Values
This function allows you to erase (reset) accumulated data without having to turn the Controller OFF.
X
MENU mode - [Setup] - [Add func] - [Logging monitor] - [Log0/1/2] - [Erase]
File Format
The format of files saved on SD card are as follows:
*1: When a warning is inserted consecutively for even one of logs 0 to 2, the measurement values are logged.
*2: Commas are aligned where logs are not set.
Example: 1,<measurement value>,,,<time>
Difference between NG count and warning count
Saving/Loading Data p.150
The display range of the graph's horizontal and vertical axes can be changed in the ADJ mode.
Adjusting Logging Monitor Conditions p.131
The "NG count" is the number of times that the measurement value exceeds or falls below the warning level.
The "warning count" is the number of times that the measurement value exceeded or fell below the warning level
continuously for the number of times set for the warning count or more in the setup conditions.
Note
<ma
x
.
v
alue>
,
<mi
n
.
v
alue>
,
<a
v
e
r
a
g
e
v
alue>
,
<s
t
a
n
da
r
d de
v
ia
t
i
on
>
,
<measu
r
eme
nt
c
o
u
nt
>
,
<N
G
c
o
u
nt
>
,
<N
G
r
a
t
e>
,
<
w
a
rn
i
ng
c
o
u
nt
>
<ma
x
.
v
alue>
,
<mi
n
.
v
alue>
,
<a
v
e
r
a
g
e
v
alue>
,
<s
t
a
n
da
r
d de
v
ia
t
i
on
>
,
<measu
r
eme
nt
c
o
u
nt
>
,
<N
G
c
o
u
nt
>
,
<N
G
r
a
t
e>
,
<
w
a
rn
i
ng
c
o
u
nt
>
<ma
x
.
v
alue>
,
<mi
n
.
v
alue>
,
<a
v
e
r
a
g
e
v
alue>
,
<s
t
a
n
da
r
d de
v
ia
t
i
on
>
,
<measu
r
eme
nt
c
o
u
nt
>
,
<N
G
c
o
u
nt
>
,
<N
G
r
a
t
e>
,
<
w
a
rn
i
ng
c
o
u
nt
>
0,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
,
<
t
ime>
1
,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
,
<
t
ime>
2,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
,
<
t
ime>
. . .
. . .
. . .
. . .
99,
<l
og
0
measu
r
eme
nt
v
alue>
,,,
<
t
ime>
0,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
1
,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
2,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
. . .
. . .
. . .
9999,
<l
og
0
measu
r
eme
nt
v
alue>
,
<l
og
1 measu
r
eme
nt
v
alue>
,
<l
og
2
measu
r
eme
nt
v
alue>
L
og
0
s
t
a
t
is
t
ical da
t
a
L
og
1 s
t
a
t
is
t
ical da
t
a
L
og
2
s
t
a
t
is
t
ical da
t
a
la
t
es
t
1 p
r
e
v
i
o
us
2
p
r
e
v
i
o
us
99
p
r
e
v
i
o
us
w
a
rn
i
ng
99
p
r
e
v
i
o
us
M
easu
r
eme
nt
r
esul
t
a
t
w
a
rn
i
ng
*1
,2
(
ma
x
. 1
00
r
esul
t
s
)
D
a
t
a is delimi
t
ed
by
a c
o
mma "
,
"
M
easu
r
eme
nt
r
esul
t
on
gr
ap
h
*
2
(
1
0,000
la
t
es
t
r
esul
t
s
)
la
t
es
t
w
a
rn
i
ng
1 p
r
e
v
i
o
us
w
a
rn
i
ng
2
p
r
e
v
i
o
us
w
a
rn
i
ng
Note
N
G
c
o
u
nt
Wa
rn
i
ng
c
o
u
nt
Wa
rn
i
ng
v
alue
(
uppe
r
limi
t)
M
easu
r
eme
nt
v
alue
80
0
1
2
2
3
4
5
6
6
0
0
0
0
0
0
1
2
2
1
05
22
77
1
0
4 1
08
111
1
0
1
99
1
00
Wa
rn
i
ng
v
alue
(
l
ow
e
r
limi
t)
4
0
Summary of Contents for Smart Sensor ZFX-C
Page 2: ......
Page 125: ...Additional Functions 122 ZFX C User s Manual MEMO ...
Page 135: ...Checking Adjusting the Measurement ADJ Mode 132 ZFX C User s Manual MEMO ...
Page 221: ...Menu List 218 ZFX C User s Manual MEMO ...
Page 225: ...INDEX 222 ZFX C User s Manual MEMO ...
Page 226: ...INDEX ZFX C User s Manual 8 APPENDICES 223 MEMO ...