![background image](http://html1.mh-extra.com/html/omron/k3np/k3np_operation-manual_743364037.webp)
28
3-4
Elapsed Time:
f4
Application example
Measures the pressing time of a printing machine.
Basic Operation
Displays in seconds the time period (T) that INA is ON. If another unit of mea-
surement is required, input an appropriate prescale value. Obtain display value
D as follows:
D (s) = T x
a
T: Time period (sec) INA is ON
a
: prescale value
To set a prescale value, refer to
4-2-4 Prescaling Menu
.
Display Value previously
measured
T
R
: Recovery time
INA
HOLD
T
1
T
R
T
2
T
3
T
4
T
4
X
a
T
2
X
a
T
1
X
a
Refer to the following table to set the most suitable prescaling value.
Mode
Unit of display
value
Prescale value
Elapsed time
sec
1
min
1/60
Where,
with operating mode 4, INB input is disregarded.
Note
The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to
4-2 Setting Mode
.
FUNCTION
SETTING
REFERENCE
Elapsed Time:
f4
Section 3-4
Summary of Contents for K3NP
Page 1: ...K3NP Period Meter Operation Manual Produced January 1998...
Page 2: ...iv...
Page 4: ...vi...