![background image](http://html1.mh-extra.com/html/omron/k3np/k3np_operation-manual_743364083.webp)
74
Reset Prohibit
·
Prohibits the resetting of the K3NP to the initial state and the resetting of max./
min. value with key input.
·
This function does not prohibit the resetting of the K3NP with external signal
input.
Setting
Default
kpon
: Key protect ON
kpoff
: Key protect OFF
kpoff
Refer to
5-3 External Input Signals
.
Follow the steps described below to set key protect ON.
Set Value LED Display Model
Basic Model
1, 2, 3...
1. Press the Mode Key for more than one second while the
prot
protect menu
is displayed. The
all
all key protect setting will appear.
Set Value LED Display Model
Basic Model
2. Press the Mode Key to display
reset
Reset prohibit setting.
Set Value LED Display Model
Basic Model
3. Press the Shift Key to display
kpoff
for changing. The PROG indicator will
flash.
Set Value LED Display Model
Basic Model
reset
FUNCTION
SETTING
MODELS
SETTING
EXAMPLE
Protect Mode
Section 4-3
Summary of Contents for K3NP