![Omron K3NP Operation Manual Download Page 26](http://html1.mh-extra.com/html/omron/k3np/k3np_operation-manual_743364026.webp)
16
K3NP with RS-422 Output Board, K31-FLK3
2-3-2 Relay Output Board
The following figures show the connections for relay output.
K3NP with 3 Relay
Output Boards,
K31-C1
K3NP with 5 Relay
Output Boards,
K31-C2
H
comparative
output
HH comparative
output
H comparative
output
PASS
output
PASS
output
L
comparative
output
L comparative
output
LL comparative
output
HH comparative
output
PASS
output
LL comparative
output
H comparative
output
L comparative
output
K3NP with 5 Relay
Output Boards,
K31-C5
The following contact output conditions are required.
5 A (resistive load) at 250 VAC
1.5 A (inductive load) at 250 VAC
5 A (resistive load) at 30 VDC
1.5 A (inductive load) at 30 VDC
Output Board
Section 2-3