3-2
Cycle:
f2
Application example
Measures the cycle with
which items pass a sensor.
Basic Operation
Displays in seconds the interval between successive occurrences of INA turning
ON. Input an appropriate prescale value to display units other than seconds. Ob-
tain display value D as follows:
D (sec) = T x
a
T: Interval between successive occurrences of INA turning ON
a
: Prescale value
By using
time
in the time unit display setting parameter, the passing time can
be displayed in units of hours, minutes, and seconds.
To set a prescale value, refer to
4-2-4 Prescaling Menu
.
Display
Value previously
measured
T
2
T
3
T
1
T
4
T
5
T
5
T
2
T
1
Refer to the following table to set the most suitable prescaling value.
Mode
Unit of display
value
Prescale value
Cycle
sec
1
min
1/60
Where,
INB input is disregarded for operating mode 2.
Note
The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to
4-2 Setting Mode
.
FUNCTION
SETTING
REFERENCE
Cycle:
f2
Section 3-2