25
3-3
Time Difference:
f3
Application example
Measures the time taken by an
object to pass between A and B.
Basic Operation
Displays the time (T) in seconds between INA turning ON and INB turning ON. If
another unit of measurement is required, input an appropriate prescale value.
Obtain the display value D as follows:
D (m/min) = T x
a
T: The time (sec) between INA turning ON and INB turning ON
a
: Prescale value
To set a prescale value, refer to
4-2-4 Prescaling Menu
.
Display
Value previously
measured
T
R
: Recovery time
T
R
Refer to the following table to set the most suitable prescaling value.
Mode
Unit of display
value
Prescale value
Time difference
sec
1
min
1/60
Note
The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to
4-2 Setting Mode
.
FUNCTION
SETTING
REFERENCE
Time Difference:
f3
Section 3-3