Chapter 5: Configuration
5.2 Set the IP Address on a Client PC's Network Adapter
Use the Maintenance Ethernet port to connect a client PC to the SetNetGo operating system.
IMPORTANT:
You must assign a static (fixed) IP address. Do not use a DHCP
server.
Configure the network adapter IPv4 address on the Client PC as follows:
1. Connect a CAT 5 Ethernet cable from the client PC’s Ethernet port to the Maintenance
Ethernet port on the EM 2100 appliance.
2. In the command field on the Windows taskbar, enter the following command to open
the Network Connections dialog:
ncpa.cpl
3. Double-click the Ethernet icon to open its Properties dialog, and then click Properties
4. Double-click TCP/IPv4 to open the Internet Protocol properties dialog.
5. Enter as the IP address: 1. 2. 3. 5, or any IP address in the range 1. 2. 3. 0 to 1. 2. 3. 255,
excluding 1. 2. 3. 4. (this is reserved for the Maintenance port).
6. Enter as the subnet mask: 255. 255. 255. 0.
7. Press
OK
to close the Internet Protocol dialog, and then press
OK
to close the Ethernet
Adapter dialog.
In future, you can use the Maintenance Ethernet port for emergency access to the Appliance at
IP address 1.2.3.4. (For example, if you lose the password or if there is a network IP address
conflict.)
5.3 Connect Your PC to SetNetGo on the Enterprise Manager
2100
SetNetGo enables you to configure and manage Enterprise Manager 2100 and AIV settings.
This section describes how to access SetNetGo through the Maintenance port to perform initial
configuration.
The user interface for SetNetGo on an Enterprise Manager appliance provides a different set of
parameters and options compared to SetNetGo on an AIV. The upper left of the screen shows
SetNetGo - ENTERPRISE MANAGER 2100 or SETNETGO - LD, depending on your SetNetGo
context (the device on which it runs, such as the Omron Adept Technologies, Inc. LD Plat-
form).
Connect to SetNetGo and Configure Access and Security
After you connect to the Maintenance Port as described in: Set the IP Address on a Client PC's
Network Adapter on page 47 you can open the SetNetGo Web interface.
NOTE:
Passwords are limited to a maximum of 20 alphanumeric characters.
For increased security, specify a long (10+ characters) password string with both
uppercase and lowercase letters. Include several integers.