38
Enterprise Manager 2100 User’s Guide
14413-200 Rev. A
4.2 Rear Panel Connectors and Features
Callout
Label
Port
Description
If you press and hold the power switch for longer than 4 seconds it
causes an immediate software halt (a
hard stop
).
4
SYS
n/a
System indicator LED. Illuminated green during normal operation.
5
HDD
n/a
Storage activity indicator LED. Illuminated red during hared drive
access (data reads and writes).
6
MAINT ETH0 Maintenance Ethernet network port. Use the Maintenance port for
initial setup, troubleshooting, and as an alternate method of access.
Its IP address is fixed at 1.2.3.4, and it requires no password.
7
MGMT
ETH1 Management Ethernet network port.
8
FLEET
ETH2 Fleet Ethernet network port. This is a general-purpose LAN con-
nection, used by both AIVs and MobilePlanner for appliance con-
nections.
9
SYNC
ETH3 Synchronize Ethernet network port. Not used in this release.
10
KEY
n/a
Front USB port (Service use only).
NOTE:
When operating in standalone configuration, the appliance uses only the
AC power, the Management Ethernet connector, and the Fleet Ethernet connector.
4.2 Rear Panel Connectors and Features
The EM2100 provides the rear panel connectors and features shown in Figure 4-2.
Figure 4-2. EM2100 Rear Panel Connectors and Features
The EM2100 rear panel connectors and features are described in Table 4-2.
Table 4-2. Description of EM2100 Rear Panel Connectors and Features
Callout
Description
1
Four USB Ports, for service use only.
2
SVGA Video DB9 port, for service use only.
3
Four auto-speed motherboard cooling fans. Fan speed (and noise volume) varies
depending on the CPU load and the ambient temperature.
4
Power supply cooling fan.
Summary of Contents for Enterprise Manager 2100