6 Programless Communications
6 - 70
E5@C Digital Temperature Controllers Communications Manual (H175)
Setting Up Communications for the Special Communication Adapter
(1) Double-click
PC Parameter
. The FX Parameter Setting Dialog Box will be displayed.
(2) We will change the communications settings for CH1.
Click the
PC System Setup (2)
Tab, change the following settings, and click the
Finish
Setup
Button. Use the defaults settings for the other parameters.
•
Operate Communication Setting: Selected.
•
Protocol: Dedicated Protocol
•
Parity: Even
•
Stop Bit: 2Bit
•
Transmission Speed: 38,400
•
H/W Type: RS-485
•
Sum Check: Selected.
•
Transmission Control Procedure: Form4 (With CR, LF)
Note: If you change the station number setting, refer to