A Appendices
A - 14
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
0×C8
Light OFF
0: Clear the setting
1: Execute
* During light OFF operation,
commands other than a
command that cancels light OFF
cannot be received.
FA
□
0
MA0
LA0
-
SA0
-
-
-
FAH0
-
0×C9
Two-point Tuning First
Point
0: Clear the setting
1: Execute
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
-
0×CA
Two-point Tuning Second
Point
1: Execute
* The Two-point Tuning First Point
command must be executed
before this command is sent.
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
-
0×CB
Position Tuning
1: Execute
* The Two-point Tuning First Point
command must be executed
before this command is sent.
FA
□
0
MA0
LA0
EA
□
0
-
-
-
-
FAH0
-
0×CC
Full Auto Tuning Setup
0: Clear the setting
1: Execute
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
0×CD
Execute Full Auto Tuning
1: Execute
* The Full Auto Tuning Setup
command must be executed
before this command is sent.
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
-
VA
□
0
FAH0
VD
□
0
0×CE
Percentage Tuning
Setting or Origin Point
Use Setting
FA
□
0, LA0, MA0, FAH0, or EA
□
0
0: Percentage tuning OFF
1: Percentage tuning ON
TA0
0: Origin point use setting ON
1: Origin point use setting OFF
FA
□
0
MA0
LA0
EA
□
0
-
-
TA0
-
FAH0
-
0×CF
Percentage Tuning Level
or Preset Value
FA
□
0, LA0, MA0, FAH0, or EA
□
0
−
99 to 99
TA0
−
19999999 to 99999999
FA
□
0
MA0
LA0
EA
□
0
-
-
TA0
-
FAH0
-
0×D0
Execute Percentage
Tuning
1: Execute
FA
□
0
MA0
LA0
EA
□
0
-
-
-
-
FAH0
-
0×D1
Power Tuning Setting,
Tolerance Setting High, or
Scaling Higher Limit
Setting
FA
□
0, LA0, MA0, or FAH0
0: Power tuning setting ON
1: Power tuning setting OFF
2: Power Tuning ON When Power
Turned On (FA
□
0 only)
TA0
−
1999999 to 9999999
AA
□
0, VA
□
0
−
1999.9999 to 9999.9999
FA
□
0
MA0
LA0
-
-
AA
□
0
TA0
VA
□
0
FAH0
-
0×D2
Power Tuning Level,
Tolerance Setting Low, or
Scaling Lower Limit
Setting
FA
□
0, LA0, MA0, or FAH0
100 to 9999
TA0
−
1999999 to 9999999
AA
□
0, VA
□
0
−
1999.9999 to 9999.9999
FA
□
0
MA0
LA0
-
-
AA
□
0
TA0
VA
□
0
FAH0
-
0×D3
Execute Power Tuning or
Execute Fine Positioning
1: Execute
FA
□
0
MA0
LA0
EA
□
0
-
-
-
-
FAH0
-
0×D4
1-point Tuning (SAO) or
Tolerance Tuning (TAO)
1: Execute
* The Full Auto Tuning Setup
command must be executed
before this command is sent.
-
-
-
-
SA0
-
TA0
-
-
-
Command
type
RWwn+2
Name
Write values
RWwm + 4: Command data 1
RWwm + 5: Command data 2
Applicable Sensor Amplifier Units