I/O Signal Assignments in Monitor Mode
n: The address assigned to the master station in the station number settings
•
On the E3NX-FA10/40, E2NC-EA10/40, E9NC-AA10/40, E9NC-VA10/40, and E9NC-VD20/50,
output data 1 and 2 of sensor numbers 1 to 16 are both fixed at "0".
Signal direction: E3NW-CCL to master
Signal direction: Master to E3NW-CCL
Device No.
Signal name
Device No.
Signal name
RXn0
Sensor No. 1 ON/OFF Output Data 1
RYn0
Do not use.
RXn1
Sensor No. 1 ON/OFF Output Data 2
RYn1
RXn2
Sensor No. 2 ON/OFF Output Data 1
RYn2
RXn3
Sensor No. 2 ON/OFF Output Data 2
RYn3
RXn4
Sensor No. 3 ON/OFF Output Data 1
RYn4
RXn5
Sensor No. 3 ON/OFF Output Data 2
RYn5
RXn6
Sensor No. 4 ON/OFF Output Data 1
RYn6
RXn7
Sensor No. 4 ON/OFF Output Data 2
RYn7
RXn8
Sensor No. 5 ON/OFF Output Data 1
RYn8
RXn9
Sensor No. 5 ON/OFF Output Data 2
RYn9
RXnA
Sensor No. 6 ON/OFF Output Data 1
RYnA
RXnB
Sensor No. 6 ON/OFF Output Data 2
RYnB
RXnC
Sensor No. 7 ON/OFF Output Data 1
RYnC
RXnD
Sensor No. 7 ON/OFF Output Data 2
RYnD
RXnE
Sensor No. 8 ON/OFF Output Data 1
RYnE
RXnF
Sensor No. 8 ON/OFF Output Data 2
RYnF
RX(n+1)0
Sensor No. 9 ON/OFF Output Data 1
RY(n+1)0
RX(n+1)1
Sensor No. 9 ON/OFF Output Data 2
RY(n+1)1
RX(n+1)2
Sensor No. 10 ON/OFF Output Data 1
RY(n+1)2
RX(n+1)3
Sensor No. 10 ON/OFF Output Data 2
RY(n+1)3
RX(n+1)4
Sensor No. 11 ON/OFF Output Data 1
RY(n+1)4
RX(n+1)5
Sensor No. 11 ON/OFF Output Data 2
RY(n+1)5
RX(n+1)6
Sensor No. 12 ON/OFF Output Data 1
RY(n+1)6
RX(n+1)7
Sensor No. 12 ON/OFF Output Data 2
RY(n+1)7
RX(n+1)8
Sensor No. 13 ON/OFF Output Data 1
RY(n+1)8
RX(n+1)9
Sensor No. 13 ON/OFF Output Data 2
RY(n+1)9
RX(n+1)A
Sensor No. 14 ON/OFF Output Data 1
RY(n+1)A
RX(n+1)B
Sensor No. 14 ON/OFF Output Data 2
RY(n+1)B
RX(n+1)C
Sensor No. 15 ON/OFF Output Data 1
RY(n+1)C
RX(n+1)D
Sensor No. 15 ON/OFF Output Data 2
RY(n+1)D
RX(n+1)E
Sensor No. 16 ON/OFF Output Data 1
RY(n+1)E
RX(n+1)F
Sensor No. 16 ON/OFF Output Data 2
RY(n+1)F
RX(n+2)0
Command Normal Completion Flags
RY(n+2)0
Trigger Request Flags
RX(n+2)1
Command Error Completion Flags
RY(n+2)1
Do not use.
RX(n+2)2
Busy Flag
RY(n+2)2
RX(n+2)3
Sensor Error Flags
RY(n+2)3
RX(n+2)4
Do not use.
RY(n+2)4
RX(n+2)5
Warning Reset Completed Flags
RY(n+2)5
Warning Reset Flags
RX(n+2)6
RX(n+13)9
Do not use.
RY(n+2)6
RY(n+13)9
Do not use.
RX(n+13)A
Error Status Flags
RY(n+13)A
Error Reset Request
Flags
RX(n+13)B
Remote Ready Flags
RY(n+13)B
Do not use.
RX(n+13)C to F
Do not use.
RY(n+13)C to F
. .
.
. . .
Summary of Contents for E3NW-CCL
Page 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Page 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 117: ......