A - 33
A Appendices
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
A-
4 Usin
g t
h
e Dis
tribu
ted
Se
nso
r U
n
it
A
A-4-6
Hardw
are S
pecificat
ions of the D
istributed Sensor
Unit
Connect the power supply cable from the Unit power supply and the DS-Bus communications cable to
this connector.
•
Connector type: Four-pin spring cage connector with lock screws
•
Applicable ferrule diameter: 0.25 to 0.5 mm
2
(AWG24 to AWG20) (Using ferrules with insulating
sleeves)
Connecting the Unit Power Supply
on page A-29 for the recommended ferrules.
Communications and Power Supply Connector
D+ terminal
D
−
terminal
+V terminal
−
V terminal
Name
Specifications
+V
D
−
24 VDC
Communications data signal
−
D+
Communications data
−
V
0 VDC
Lock screws