4 - 5
4 Mounting and Wiring
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
4-
2 W
irin
g
t
h
e CC
-Lin
k Net
w
o
rk
4
4-
2-2 Pr
ep
aring for
Wir
ing
FANC-110SBH CC-Link Cable (Kuramo Electric Co.)
Refer to documentation for the CC-Link master unit and the
CC-Link Installation Guide
for
specifications and processing methods (including stripping methods) for the special CC-Link cable.
Network connector 35505-6000-B0MGF (Sumitomo 3M)
Two are provided as accessories.
1
Strip 4 cm of the insulating sheath from the CC-Link Version 1.10-compliant cable.
2
Separate the braided shield and drain wires, and then twist the drain wire with your
fingers at least 10 times.
Be careful not to sever the drain wire.
3
Cut off the braided shield, ALPET shield tape, and filler.
4
Separate the wires so that they are in the following order: blue, white, yellow, and drain
wire.
Blue wire, pin 1 (cover label: DA B)
White wire, pin 2 (cover label: DB W)
Yellow wire, pin 3 (cover label: DG Y)
Drain wire, pin 5 (cover label: SL D)
5
Insert the cable all the way into the power clamp.
Check to confirm that the wire has been inserted all the way by looking through the top of the
cover.
6
Use pliers to push the cover into the body and crimp the cable.
7
Check to confirm that the cover is level with the body and that there is no space between
the body and the cover.
* We recommend using heat-shrinking tubing to protect the drain wire and other wiring.
Reference
For details, refer to the
3M Power Clamp Connector Wiring Procedures
.
4-2-2
Preparing for Wiring
Wiring the Connector
Summary of Contents for E3NW-CCL
Page 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Page 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 117: ......