A - 3
A Appendices
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
A-
1 Usin
g Co
mm
and
s fo
r C
o
m
m
un
icat
ions
A
0×0B
Check Communications
Unit Software Version
The value is read as a binary
number.
To communication unit
0x0C
Communication Unit ID
Confirmation
The value is read as a hexadecimal
number.
To communication unit
0×20
Read Detection Level
−
1999 to 9999 (FA
□
0, LA0, SA0,
MA0, FAH0, or EA
□
0)
−
19999999 to 99999999 (TA0,
AA
□
0, or VA
□
0)
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
0×22
Read Peak Detection
Level
−
1999 to 9999 (FA
□
0, LA0, SA0,
MA0, FAH0, or EA
□
0)
−
19999999 to 99999999 (AA
□
0 or
VA
□
0)
* "Minimum input peak value and
maximum interrupted light
bottom value [P-b]" or "PEAK"
(detection level at peak) must be
selected with the Display Switch
(B0 hex).
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
-
VA
□
0
FAH0
-
0×24
Read Bottom Detection
Level
−
1999 to 9999 (FA
□
0, LA0, SA0,
MA0, FAH0, or EA
□
0)
−
19999999 to 99999999 (AA
□
0 or
VA
□
0)
* You must select the input peak
minimum value and maximum
interrupted light bottom value
[P-b] for the Display Switch
Setting (B0 hex).
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
-
VA
□
0
FAH0
-
0×27
Read Zero Reset Level
−
9999 to 0 (FA
□
0, LA0, SA0, MA0,
FAH0, or EA
□
0)
−
99999999 to 0 (AA
□
0 or VA
□
0)
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
-
VA
□
0
FAH0
-
0×28
Read Sensor Status
(tuning status, mutual
interference status, etc.)
The bits listed below will turn ON
when the conditions for an alarm
are met.
Bit 00: Normal operation (This bit is
normally set to 1, and changes to 0
if any bit 08 or higher changes to
1.)
Bit 01: CH1 DPC status (This bit is
set to "1" when the DPC is ON.)
Bit 02: CH1 Smart Tuning Status
(This bit is set to "1" when ST is
ON.)
Bit 03: CH2 DPC status (This bit is
set to "1" when the DPC is ON.)
*MA0 only
Bit 04: CH2 Smart Tuning Status
(This bit is set to "1" when ST is
ON.)
*MA0 only
Bit 05 to 07: Not used.
Bit 08: DPC Error (FA
□
0, LA0,
MA0, or FAH0 only)
Bit 09: EEPROM Error (response
or checksum)
Bit 0A: Load Short Error
Bit 0B: Head Error (SA0 or TA0 only)
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
Command
type
RWwn+2
Name
Read values
RWrm+2: Received Data 1 Area
RWrm+3: Received Data 2 Area
Applicable Sensor Amplifier Units