6 - 9
6 E3NW-CCL Function Specifications
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
6-1 I/O Dat
a Assig
n
m
ent
s
6
6-
1-1 Inpu
t Dat
a Assignment
s
*1 The HIGH threshold value cannot be specified during area output. Use a command to read this value.
*2 The same data is read, regardless of IN1/IN2.
n: The address assigned to the master station in the station number settings
*1 Cannot be used on the E9NC-TA0/AA
0/VA
0/VD
0. Set to "0".
Write area: Master to E3NW-CCL
Device No.
Description
Remarks
RWwn
Command Unit Number Setting Area
RWwn+1
Command Sensor Channel Setting Area
RWwn+2
Command Type Setting Area
Refer to
.
RWwn+3
Do not use.
RWwn+4
Command data 1
RWwn+5
Command data 2
RWwn+6 to 7
Do not use.
RWwn+8
Detection Level/Threshold Value Switch Setting Area
ON = Threshold value,
OFF = Detection level
RWwn+9
IN1/IN2 Switch Setting Area
*1
ON = IN2, OFF = IN1
RWwn+A
Detection Level Setting Area
*1
2 = Detection level peak,
1 = Detection level
bottom, 0 = Detection
level/Threshold value
RWwn+B to 2F
Do not use.