A Appendices
A - 4
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
0×29
Sensor Model
FA
□
0/FAH0: 0160
FA10/40: 01D0
LA0: 0260
SA0: 0360
TA0: 0460
MA0: 0560
AA0: 0860
AA10/40: 08D0
VA0: 0960
VA10/40: 09D0
EA0: 0A60
EA10/40: 0AD0
VD0: 0b61
VD20/50: 0bD5
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
0x2A
Sensor ID
The value is read as a hexadecimal
number.
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
0×40
Threshold Setting 1
−
1999 to 9999 (FA
□
0, LA0, SA0,
MA0, FAH0, or EA
□
0)
−
19999999 to 99999999 (TA0,
AA
□
0, or VA
□
0)
-9999 to 9999 (VD
□
0)
* This is the threshold value in
Normal Detection Mode or the
low threshold value in Area
Detection Mode.
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
0×41
Threshold Setting 2
−
1999 to 9999 (FA
□
0, LA0, SA0,
MA0, FAH0, or EA
□
0)
−
19999999 to 99999999 (TA0,
AA
□
0, or VA
□
0)
-9999 to 9999 (VD
□
0)
* This is the high threshold value in
Area Detection Mode.
FA
□
0
MA0
LA0
EA
□
0
SA0
AA
□
0
TA0
VA
□
0
FAH0
VD
□
0
Command
type
RWwn+2
Name
Read values
RWrm+2: Received Data 1 Area
RWrm+3: Received Data 2 Area
Applicable Sensor Amplifier Units
Summary of Contents for E3NW-CCL
Page 1: ...E3NW CCL CC Link Digital Sensor Communications Unit User s Manual Cat No E431 E1 08 ...
Page 114: ...A Appendices A 34 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 116: ...B B 2 E3NW CCL CC Link Digital Sensor Communications Unit User s Manual E431 ...
Page 117: ......