5 E3NW-CCL Hardware Specifications
5 - 8
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
•
Connector configuration: RJ45 8-pin modular connector (ISO 8877 standard)
•
Terminal Arrangement
Connect the Unit power supply (24 VDC).
•
Connector type: Two-pin spring cage connector with lock screws
•
Applicable ferrule diameter: 0.25 to 0.5 mm
2
(AWG24 to AWG20) (Using ferrules with insulating
sleeves)
4-3-3 Connecting the Unit Power Supply
Contact
resistance
Initial contact resistance: 50
m
Ω
max. The increase in
contact resistance after each
environmental test is
performed must be no more
than 25 m
Ω
.
Perform measurements with a resistance measurement current
of 1 mA and open voltage of 20 mV using the 4-terminal
method. (This assumes that applicable OMRON connectors
are used and includes contact bulk resistance.)
•
3M Sequence 1: 50 hot-swaps -> Humidity resistance testing
-> Saltwater spray testing
•
3M Sequence 2: Thermal shock testing -> Humidity testing ->
Vibration testing
•
3M Sequence 3: High-temperature lifetime testing
•
H
2
S Gas Sequence: 50 hot-swaps -> H
2
S gas testing
•
Hot-swap durability testing: 500 hot-swaps
* Refer to
Table 1
for the environmental testing conditions.
Name
Function
DA
Communications signal
DB
Communications signal
DG
Communications signal
NC
Not used.
SLD
Connect the CC-Link connection
cable’s shield wire.
5-3-4
Unit Power Supply Connector
Item
Standard
Conditions
Name Specifications
+V
−
V
24 VDC
0 VDC
FG
Functional ground terminal
+V terminal
−
V terminal
FG
Lock