6 - 5
6 E3NW-CCL Function Specifications
E3NW-CCL CC-Link Digital Sensor Communications Unit User’s Manual (E431)
6-1 I/O Dat
a Assig
n
m
ent
s
6
6-
1-1 Inpu
t Dat
a Assignment
s
Read/Write Register Assignments in Reduced I/O Mode
m: The address assigned to the master station in the station number settings
n: The address assigned to the master station in the station number settings
Read area: E3NW-CCL to master
Device No.
Description
Remarks
RWrm
Sensor Warning Flags (1 to 16)
RWrm+1
Do not use.
RWrm+2
Received Data 1 Area
RWrm+3
Received Data 2 Area
RWrm+4
Number of Mounted Sensors (including Dummy
Slaves)
RWrm+5
Error Information Storage Area
Error type
Refer to
RWrm+6 and 7
Do not use.
Write area: Master to E3NW-CCL
Device No.
Description
Remarks
RWwn
Command Unit Number Setting Area
RWwn+1
Command Sensor Channel Setting Area
RWwn+2
Command Type Setting Area
Refer to
.
RWwn+3
Do not use.
RWwn+4
Command data 1
RWwn+5
Command data 2
RWwn+6 and 7
Do not use.